Chinese Journal of Biologicals ; (12): 65-71, 2024.
Article in Chinese | WPRIM | ID: wpr-1006201

ABSTRACT

@#Objective To develop and verify a whole column imaging detection-capillary isoelectric focusing(WCID-CIEF)method for the determination of isoelectric point(pI)of pertactin(PRN).Methods The WCID-CIEF method for the determination of PRN antigen was developed by optimizing the parameters such as the focusing time and final concentration of samples in the WCID-CIEF process,and verified for the specificity,accuracy,repeatability,intermediate precision,durability and inter-batch consistency.Results The optimal focusing time of WCID-CIEF for the determination of PRN antigen pI was 1 min at 1 500 V and 3 min at 3 000 V. The optimal final concentration of PRN antigen was 300 μg/mL. The PRN antigen pI was about 6. 035,and the blank matrix showed no interference peak in the position of each peak of antigen. The method had good specificity,accuracy,repeatability,intermediate precision,durability and consistency among batches.Conclusion The developed WCID-CIEF method is suitable for the pI detection and charge heterogeneity analysis of PRN antigen,which can provide basis for the characterization of PRN antigen and reference for the quality control in the process of development and production of related vaccines.

2.
Chinese Journal of Biologicals ; (12): 1-7+16, 2024.
Article in Chinese | WPRIM | ID: wpr-1006189

ABSTRACT

@#Objective To analyze the trend of the hemagglutinin(HA) and ovalbumin contents in the lot release of influenza virus split vaccines in 2021,and evaluate the quality and quality control level of the vaccines.Methods The HA and ovalbumin content data of influenza virus split vaccines from two domestic enterprises in 2021 were collected and collated. The mean value and standard deviation were calculated according to the first 40 batches of data of the enterprise in the year,and the warning limit and action limit were established. The trend analysis of the above indexes was carried out to evaluate the stability and consistency of the product quality of the enterprise. Statistical data comparison and consistency analysis were made between the test results of the batch inspected by the lot release institution and the results of the enterprise.Results Through the retrospective data analysis of quadrivalent influenza virus split vaccines from two vaccine enterprises A and B,it was found that the content of H1N1 subtype HA and ovalbumin in the two enterprises and the content of Bv HA in the B enterprise had out of trend(OOT)situations,while the trend of other items was stable. The results of paired student's t test or Wilcoxon signed-rank test of the samples inspected by the lot release institution showed that except Bv subtype HA(t = 1. 094 and 0. 742 respectively)and ovalbumin(w =-64 and 36 respectively)contents showed no statistically significant difference(P > 0. 05),the HA contents of H1N1(t = 3. 862,w = 232),H3N2(t = 8. 225 and3. 473 respectively)and By(t = 5. 616 and 4. 934 respectively)of the two enterprises had significant differences(P <0. 05). The results of enterprises were generally higher than the lot release institution. Bland-Altman test analysis found that the consistency between the test data of enterprise A's HA content and the data of the lot release institution was better than that of enterprise B.Conclusion The stability and consistency of data trends of active ingredients and main impurity ingredients of quadrivalent influenza virus split vaccine batches in 2021 were generally good. The trend analysis can identify potential problems in vaccine production,and enterprises should carefully implement trend analysis and effectively monitor the product quality of vaccines.

3.
Journal of Pharmaceutical Practice ; (6): 1-5, 2024.
Article in Chinese | WPRIM | ID: wpr-1005419

ABSTRACT

Sprays have gained significant attention and widespread use due to their numerous advantages, including rapid action, safety, and convenience. They are widely used in various fields such as dermatology, respiratory disease treatment, wound repair, and central nervous system targeted drug delivery. With the in-depth research of new drugs and modern pharmaceutics, the development ideas of sprays are more diverse, and the application scenarios are increasingly extensive. In this review the clinical application status of sprays and the latest research progress were summarized. Then the quality control parameters were briefly introduced,which provided reference for the research and development of sprays.

4.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 12-20, 2024.
Article in Chinese | WPRIM | ID: wpr-1005248

ABSTRACT

In the quality control of Chinese medicine, the detection of active components and toxic and harmful components are two important links. Although conventional methods such as high performance liquid chromatography and liquid chromatography-mass spectrometry can accurately quantify the above substances, they have shortcomings such as complicated operation, high costs, inability of detection at any time, difficult detection of insoluble and macromolecular substances. Enzyme-linked immunosorbent assay (ELISA) can adsorb antigens or antibodies on the surface of solid carriers and realize qualitative or quantitative analysis of targets by using the specific reactions of antigens and antibodies. This method is praised for the simple operation, high sensitivity, strong specificity, simple requirements for experimental equipment, a wide application range, and low costs. In recent years, ELISA has been widely used in the quality control of Chinese medicine, especially in the content determination of mycotoxins represented by aflatoxin and the qualitative and quantitative analysis of active components. ELISA plays an increasingly important role with its unique advantages, providing new methods and ideas for the rapid quality examination of large quantities of Chinese medicines. This paper reviews the research progress in ELISA for the quality control of Chinese medicine in recent years and prospects its technical development and application prospects, aiming to provide reference and research ideas for further using this method to ensure the quality, safety, and controllability of Chinese medicine.

5.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 255-263, 2024.
Article in Chinese | WPRIM | ID: wpr-999183

ABSTRACT

Diabetic peripheral neuropathy(DPN) is a neurodegenerative disease of diabetes mellitus involving peripheral nervous system damage, which is characterized by axonal degenerative necrosis, Schwann cell apoptosis and demyelination of nerve myelin sheath as the main pathological features, this disease is highly prevalent and is a major cause of disability in diabetic patients. Currently, the pathogenesis of DPN may be related to oxidative stress, inflammatory response, metabolic abnormality, and microcirculation disorder. The treatment of DPN in modern medicine mainly starts from controlling blood glucose, nourishing nerves and improving microcirculation, which can only alleviate the clinical symptoms of patients, and it is difficult to fundamentally improve the pathological damage of peripheral nerves. Mitochondrial quality control refers to the physiological mechanisms that can maintain the morphology and functional homeostasis of mitochondria, including mitochondrial biogenesis, mitochondrial dynamics, mitochondrial oxidative stress and mitochondrial autophagy, and abnormal changes of which may cause damage to peripheral nerves. After reviewing the literature, it was found that traditional Chinese medicine(TCM) can improve the low level of mitochondrial biogenesis in DPN, maintain the balance of mitochondrial dynamics, inhibit mitochondrial oxidative stress and mitochondrial autophagy, and delay apoptosis of Schwann cells and neural axon damage, which has obvious effects on the treatment of DPN. With the deepening of research, mitochondrial quality control may become one of the potential targets for the research of new anti-DPN drugs, therefore, this paper summarized the research progress of TCM in treating DPN based on four aspects of mitochondrial quality control, with the aim of providing a theoretical research basis for the discovery of new drugs.

6.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1535404

ABSTRACT

Introducción: La calidad de los datos facilita garantizar la fiabilidad de los estudios observacionales. Objetivo: Describir el aseguramiento y el control de calidad para mantener la fiabilidad y la validez del dato en un estudio de cohorte. Métodos: Presentar el manejo de datos implementado dentro de un seguimiento de enfermos renales crónicos cuya exposición fue un programa de protección renal comparado con el tratamiento convencional y su asociación con desenlaces clínicos. Se evaluó el cambio en la frecuencia de errores después de implementar el plan y la reproducibilidad del ingreso de registros a las bases de datos. Resultados: Se documentó una disminución progresiva en los errores cometidos en la captación de datos. El valor de Kappa entre los recolectores de la información para las variables clínicas más importantes fue 0,960 para la depuración de creatinina 150 mg/dL; 0,730 para la alteración del sedimento urinario; 0,956 para la asignación de estadio al ingreso. Los coeficientes de correlación intraclase para la identificación de las cifras de presión arterial sistólica fue 0,996; para la de presión arterial diastólica 0,993 y para los niveles de creatinina sérica al diagnóstico 0,995. Discusión: La calidad de los datos comienza con el reconocimiento de los retos y dificultades que implica su responsable captación, de ahí el aporte de la estandarización de los procesos y el personal que los lleve a cabo en forma idónea. Estudios evidencian que muchos procesos de mejora surgen en el desarrollo de la investigación sin protocolos preestablecidos. Conclusión: La reducción en la proporción y el tipo de error durante el proceso de captación de datos se debe a su identificación temprana y la corrección de instructivos, del instrumento de control de diligenciamiento y de la capacitación continua del personal. El análisis mostró una buena concordancia interevaluador.


Introduction: Data quality makes it easier to ensure that observational studies are reliable. Objective: To describe assurance and quality control to maintain data reliability and validity in a cohort study. Methodology: We present the data management strategies implemented in a study that followed patients of chronic kidney disease who were in a renal protection program and compared them with those undergoing conventional treatment to observe its association with clinical outcomes. We assessed the changes in error frequency after implementing the plan along with the reproducibility of the strategies for entering records into the databases. Results: We documented a progressive decrease of data collection errors. The Kappa values among data collectors for the most important variables were: 0.960 for creatinine clearance 150 mg/dl; 0.730 for urinary sediment alteration and 0.956 for stage allocation upon admission. The intraclass correlation coefficient for the identification of systolic blood pressure was 0.996; for diastolic blood pressure, the coefficient was 0.993 and for serum creatinine levels at diagnosis, the value was 0.995. Discussion: Data quality begins with the recognition of the challenges and difficulties involved in responsible data collection, hence the contribution of standardized processes and personnel to carry them out in a suitable manner. Studies show that many improvement processes arise in the development of research without pre-established protocols. Conclusion: The reduction in error ratio and type during the data collection process are the result of the early identification of erroneously entered or missing data, the correction of the guidelines for completing forms as well as of the instruments for detecting errors and continuous training of the staff. The analysis showed good inter-rater reliability.

7.
Rev. mex. anestesiol ; 46(2): 87-92, abr.-jun. 2023. tab, graf
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1508624

ABSTRACT

Resumen: Introducción: El diferimiento quirúrgico desde el inicio de la pandemia COVID-19 representa un riesgo para la salud de los pacientes y un reto para las instituciones sanitarias. La métrica de indicadores de productividad en quirófano, como la tasa de diferimiento quirúrgico, nos brindará información para planear estrategias basadas en evidencia científica que nos permitan mejorar la calidad de la atención. Objetivo: Determinar la tasa de diferimiento quirúrgico durante la pandemia COVID-19. Material y métodos: Se realizó un estudio, retrospectivo, descriptivo y transversal en el que se analizaron 297 pacientes cuyas cirugías fueron diferidas durante el período comprendido del 11 de marzo de 2020 al 10 de marzo de 2021. Para el análisis de variables se efectuó estadística descriptiva, utilizando medidas de tendencia central y dispersión, frecuencias simples y proporciones. Adicionalmente se realizó un diagrama de Pareto. La información fue procesada con SPSS v-25.0. Resultados: La proporción de diferimiento fue de 7.34%; 20.92% de las causas fueron atribuidas al paciente, 31.65% a causas médicas y 47.49% fueron logístico-administrativas. Conclusión: Las causas de diferimiento quirúrgico establecidas son evitables y revelan fracasos en los procesos logístico-administrativos que requieren planes de mejora continua.


Abstract: Introduction: Surgical deferral since the beginning of the COVID-19 pandemic represents a risk to the health of patients and a challenge for health institutions. The metric of productivity indicators in the operating room, such as the surgical deferral rate, will provide us with information to plan strategies based on scientific evidence that allow us to improve the quality of care. Objective: To determine the surgical deferral rate during the COVID-19 pandemic. Material and methods: A retrospective, descriptive and cross-sectional study was carried out in which 297 patients whose surgeries were deferred during the period from March 11, 2020 to March 10, 2021 were analyzed. Descriptive statistics were employed, using measures of central tendency and dispersion, simple frequencies and proportions. Additionally, a Pareto diagram was made. The information was processed with SPSS v-25.0. Results: The deferral rate was 7.34%. 20.92% of the causes were attributed to the patient, 31.65% to medical causes and 47.49% logistic-administrative. Conclusion: The established causes of surgical deferral are avoidable and reveal failures in the logistical-administrative processes that require continuous improvement plans.

8.
Article in Spanish | LILACS-Express | LILACS | ID: biblio-1535126

ABSTRACT

Objetivo: Optimizar el control interno de calidad de RT-PCR en tiempo real para detección cualitativa de SARS-CoV-2, utilizando los valores Cq de controles negativos y positivos. Material y método: Estudio prospectivo-longitudinal. La muestra estuvo constituida por 143 valores Cq para los controles negativos de alicuotado y extracción, así como para el control positivo. Se analizó la distribución normal de los valores Cq mediante la prueba de Anderson-Darling (AD) y se aplicaron pruebas de aleatoriedad. Se calculó límites de control a partir de 51 valores Cq, para luego, mediante gráficas de control, monitorizar 92 valores Cq obtenidos desde noviembre del 2020 hasta marzo del 2021. Se evaluó aceptación de lote e índices Cpk como indicadores de optimización. Los cálculos se hicieron con el programa Minitab. Resultados: Se aceptaron los lotes de valores Cq y se obtuvieron índices Cpk superiores a 1.33 para los tres tipos de control. Discusión: No existen estudios publicados que apliquen control estadístico de calidad a la detección cualitativa de SARS-CoV-2. Conclusiones: Es posible utilizar los valores Cq de los controles para optimizar el control interno de calidad de RT-PCR en tiempo real para detección cualitativa de SARS-CoV-2, como si se tratara de una técnica de tipo cuantitativo.


Objective: To optimize the internal quality control of real-time RT-PCR for the qualitative detection of SARS-CoV-2, using the Cq values ​​of negative and positive controls. Material and method : Prospective-longitudinal study. The sample consisted of 143 Cq values for the negative aliquot and extraction controls, as well as for the positive control. The normal distribution of Cq values ​​was analyzed using the Anderson-Darling (AD) test and randomness tests were applied. Control limits were calculated from 51 Cq values, and then, using control charts, to monitor 92 Cq values ​​obtained from November 2020 to March 2021. Lot acceptance and Cpk indices were evaluated as optimization indicators. The calculations were made with the Minitab program. Results: The batches of Cq values ​​were accepted and Cpk indices higher than 1.33 were obtained for the three types of control. Discussion : There are no published studies that apply statistical quality control to the qualitative detection of SARS-CoV-2. Conclusions : It is possible to use the Cq values ​​of the controls to optimize the internal quality control of real-time RT-PCR for qualitative detection of SARS-CoV-2, as if it were a quantitative technique.

9.
Chinese Journal of Radiological Medicine and Protection ; (12): 614-619, 2023.
Article in Chinese | WPRIM | ID: wpr-993133

ABSTRACT

Objective:To provide reference for establishing the testing method for quality control of neutron beam in boron neutron capture therapy (BNCT) equipment in China by testing the radiation characteristic parameters and dosimetry characteristic parameters of epithermal neutron beam in hospital neutron irradiator (IHNI).Methods:By comparing the uncertainties in the result of various test items with the deviation values recommended by the European Joint Research Center (EC-JRC), the feasibility of the relevant of testing method was analyzed and evaluated.Results:The uncertainty in epithermal neutron fluence rate was 2.7%. The uncertainty in ratio of thermal to epithermal neutron fluence rate was 3.1%. The uncertainty in ratio of fast neutron air kerma to epithermal neutron fluence rate was 9.3%. The uncertainty in ratio of gamma air kerma to epithermal neutron fluence rate was 8.7%. The uncertainty in spatial distribution of neutron fluence rate was 2.7%. The uncertainty in thermal neutron fluence rate in phantom was 1.8%. The uncertainty in neutron and gamma-ray dose rate in phantom was 17.1% and 4.0%, respectively.Conclusions:The uncertainty in neutron dose rate measurement result in phantom is higher, and further research is needed to improve the accuracy of the testing method. The uncertainty in the measurement result of other test items is lower, and the accuracy of the test result is expected to meet the allowable deviation value recommended by the European Joint Research Center, and the test method is feasible.

10.
Chinese Journal of Radiological Medicine and Protection ; (12): 63-67, 2023.
Article in Chinese | WPRIM | ID: wpr-993052

ABSTRACT

Objective:To analyze the conventional quality control result of Leksell Icon Gamma Knife cone-beam CT and evaluate long-term stability of cone-bem CT.Methods:QA TOOL Plus was used to verify the accuracy of cone-beam CT. The phantom Catphan 503 was scanned, and the image spatial resolution, contrast to noise ratio and homogeneity were analyzed.Results:The maximum deviation in image volume of cone-beam CT was 0.09-0.17 mm, which passed the accuracy test. At the scanning patterns with CT dose index of 2.5 and 6.3 mGy, the spatial resolution was very stable at 7 and 8 lp/cm respectively. The contrast noise ratio and uniformity meet the reference requirements.Conclusions:The conventional quality control results of Leksell Icon Gamma Knife cone-beam CT are stable in 12 months. In addition to referring to the manufacturer′s baseline value, the unified analysis and evaluation standard for Gamma Knife need to be further improved for the quality control of cone-beam CT.

11.
Journal of Chinese Physician ; (12): 691-694,699, 2023.
Article in Chinese | WPRIM | ID: wpr-992362

ABSTRACT

Objective:To investigate the effect of intravenous anesthesia on the detection rate of lesions in diagnostic gastroscopy.Methods:A total of 9 071 subjects who underwent diagnostic gastroscopy at the Digestive Endoscopy Center of Yangzhou University Affiliated Hospital from March 2021 to February 2022 were selected. Data were collected from the gastroscopy quality control system, including age, gender, examination physician, Helicobacter pylori infection, examination method, withdrawal time, number of images left, number of biopsies, biopsy site, gastroscopy diagnosis, pathological diagnosis, etc. They were divided into anesthesia group and general group based on the examination method, and propensity score matching (PSM) was performed on the two groups of subjects. Excluding confounding factors, the detection of lesion location and lesion type in two groups of subjects was analyzed; Simultaneously, univariate and multivariate logistic regression analysis was used to analyze the influencing factors of the detection rate of precancerous lesions and malignant tumors in the upper gastrointestinal tract.Results:After PSM, 1 655 subjects were included in both groups. In terms of lesion location, the detection rate of gastric body lesions in the anesthesia group was higher than that in the general group ( P<0.05), and the detection rate of esophageal lesions in the anesthesia group was lower than that in the general group ( P<0.05); In terms of lesion types, the detection rate of precancerous lesions such as gastric polyps, mucosal protrusions, mucosal atrophy, and intestinal metaplasia in the anesthesia group was higher than that in the general group (all P<0.05). The results of logistic regression analysis showed that intravenous anesthesia was an independent influencing factor for the detection rate of precancerous lesions and malignant tumors in diagnostic gastroscopy ( OR=1.338, 95% CI: 1.070-1.674, P<0.05). Conclusions:Intravenous anesthesia is an independent influencing factor for the detection rate of precancerous lesions and malignant tumors in diagnostic gastroscopy, and can improve the detection rate of upper gastrointestinal lesions.

12.
Chinese Journal of Endemiology ; (12): 675-678, 2023.
Article in Chinese | WPRIM | ID: wpr-991692

ABSTRACT

Objective:To analyze the external quality control assessment results of urinary iodine, salt iodine and water iodine in iodine deficiency disorders laboratories in Qinghai Province, to evaluate the testing capacity of provincial, municipal and county-level laboratories and the operation of external quality control network, so as to provide quality assurance for consolidating and eliminating iodine deficiency disorders.Methods:In 2021, 1 provincial, 8 municipal, and 43 county-level laboratories in Qinghai Province had participated in the assessment of urinary iodine and salt iodine, while 1 provincial and 8 municipal-level laboratories had participated in the assessment of water iodine. The assessment results were evaluated using the method of reference value ± uncertainty of external quality control samples.Results:All laboratories that participated in the assessment had provided feedback. One provincial-level laboratory passed the assessment of urinary iodine, salt iodine, and water iodine. Among 8 municipal-level laboratories, 2 laboratories failed the urinary iodine assessment, with a pass rate of 6/8; the assessment of salt iodine and water iodine in 8 laboratories were all qualified. Among 43 county-level laboratories, 7 laboratories failed the urinary iodine assessment, with a pass rate of 83.7% (36/43); the assessment of salt iodine in 43 laboratories were all qualified.Conclusions:The external quality control network of iodine deficiency disorders laboratories in Qinghai Province has fully covered all municipal and county-level laboratories. The testing capability of provincial-level laboratory is stable and maintains a high level; the testing quality of some municipal and county-level laboratories is still unstable and needs to be further strengthened.

13.
Chinese Journal of Endemiology ; (12): 65-68, 2023.
Article in Chinese | WPRIM | ID: wpr-991580

ABSTRACT

Objective:To learn about the detection quality and external quality control assessment of fluoride and arsenic in laboratories at all levels in Qinghai Province.Methods:The Z-score method was used to analyze and evaluate the evaluation results of 1 provincial, 8 municipal and 43 county level laboratories of disease prevention and control institutions participating in the external quality control assessment of water fluoride and brick tea fluoride in Qinghai Province in 2021, as well as 1 provincial, 1 municipal and 2 county level laboratories of disease prevention and control institutions participating in the external quality control assessment of water arsenic and urine arsenic. The feedback rate and qualification rate of external quality control of each assessment laboratory were calculated.Results:In 2021, the feedback rate of external quality control of water fluoride, brick tea fluoride, water arsenic and urine arsenic in provincial and municipal level laboratories of Qinghai Province were 100.00%; except that the qualified rate of water fluoride was 7/9, the qualified rate of external quality control of other projects was 100.00%. The feedback rate of external quality control of water fluoride, brick tea fluoride, water arsenic and urine arsenic in county level laboratories was 100.00%; except that the qualified rate of water fluoride was 86.05% (37/43), the qualified rate of external quality control of other projects was 100.00%. In the specific assessment results of the laboratory, the assessment results of water fluoride sample FS20210101 from 1 provincial, 1 municipal and 2 county level laboratories, and FS20210102 from 1 county level laboratory were suspicious; the assessment results of water fluoride sample FS20210101 from 3 county level laboratories were not satisfactory; the assessment results of fluoride and arsenic sample in other laboratories were satisfactory.Conclusions:The qualified rate of external quality control of fluoride and arsenic in laboratories at all levels in Qinghai Province is relatively high, but some county level laboratories are still dissatisfied with the assessment results of water fluoride. Therefore, it is necessary to strengthen the detection level of water fluoride in laboratories.

14.
Chinese Journal of Radiological Health ; (6): 281-287, 2023.
Article in Chinese | WPRIM | ID: wpr-978430

ABSTRACT

In 2003, the responsibility of radiation source safety supervision was redivided and transferred from the health department to the environmental protection department. After the promulgation and implementation of the Rule on the Administration of Radiodiagnosis and Radiotherapy in 2006, due to the incorporation of a large number of medical practice supervision rules, the radiation health supervision of medical institutions has evolved into the radiodiagnosis and radiotherapy supervision. In the past 16 years, radiation, occupational health supervision, and medical practice supervision have not been well integrated, and there are many legal problems in radiodiagnosis and radiotherapy supervision. The regulation rules of environmental protection, metrology, and other relevant departments on radiation sources and radiation devices have been constantly changing, resulting in overly complex regulatory requirements on radiodiagnosis and radiotherapy, which increases the burden of medical institutions. This paper reviews the historical evolution and legal system changes of radiodiagnosis and radiotherapy supervision, analyzes the problems and challenges faced by the relevant regulatory departments, and proposes ways to improve the supervision system.

15.
Chinese Journal of Radiological Health ; (6): 235-239, 2023.
Article in Chinese | WPRIM | ID: wpr-978421

ABSTRACT

Objective To analyze the results of national personal dose monitoring intercomparison and assessment of Hubei Provincial Hospital for Occupational Disease in 2016—2021, to investigate the influencing factors for monitoring results, and to improve the ability of personal dose monitoring. Methods The assessment was completed according to the requirements of The National Comparison Scheme for Individual Dose Monitoring Ability and Testing Criteria of Personnel Dosimetry Performance for External Exposure (GBZ 207—2016). Results The assessment results were qualified in 2016—2017 and 2020 and excellent in 2018—2019 and 2021. Conclusion The ability of personal dose monitoring in our laboratory has been continuously improved. The monitoring results are accurate and the data processing is standardized, which meet the requirements of relevant standards for personal external exposure dose monitoring.

16.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 158-164, 2023.
Article in Chinese | WPRIM | ID: wpr-976551

ABSTRACT

Strengthening the standard formulation and quality management of traditional Chinese medicine(TCM) dispensing granules is an important part of the strategic planning for the development of TCM in China. In order to examine the clinical application and overall quality control of the existing national standards for TCM dispensing granules, this study classified and summarized the varieties in the existing standards, analyzed their clinical applicability, and discussed the characteristics of the test methods for identification, content determination and specific chromatogram/fingerprint. It was found that the coverage of the existing standards was inadequate in terms of quantity, and it was even weaker in the aspects of therapeutic efficacy, herb family, processing method and preparation method of TCM dispensing granules. It was concluded that the characteristics of national standards in test methods were summarized as follows:guided by clinical application, based on the reference system, taking specific chromatogram as a breakthrough, so as to improve the overall quality control of TCM dispensing granules. It is suggested that the coverage of national standards should be subsequently expanded to meet the needs of market development. In order to enhance clinical applicability, the content of national quality standards should be increased, including increasing variety diversity to meet the needs of clinical application, raising the standard requirements to improve the clinical medication experience, and strengthening effectiveness research to highlight clinical efficacy. At the same time, the accessibility of regulatory inspection is enhanced, the rules for the management of varieties without national standards are promulgated to lay the foundation for the healthy and orderly development of TCM dispening granule industry.

17.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 166-172, 2023.
Article in Chinese | WPRIM | ID: wpr-973758

ABSTRACT

ObjectiveTo analyze the polarized light microscopic characteristics, the composition of physical phases and their relative contents of Maifanitum from different origins, and to establish the Fourier characteristic fingerprint of Maifanitum powder crystals by X-ray diffraction(XRD). MethodA total of 26 batches of Maifanitum samples were selected, and the microscopic characteristics of the sample powders and grinding flakes were observed by polarized light microscopy under single polarized light and orthogonal polarized light, and the main phase compositions and their relative contents were analyzed by powder crystal XRD technique, and the XRD Fourier characteristic fingerprint of Maifanitum was established. The incident light source of XRD was Cu target Kβ radiation, the light tube voltage and light tube current were 40 kV and 40 mA, respectively, the divergence slit was 1°, the scattering slit was 1°, the receiving slit was 0.2 mm, the scanning speed was 5°·min-1 with continuous scanning and scanning range of 5-90°(2θ), and the step length was 0.02°. ResultThe polarized light micrographs of powders and grinding flakes of Maifanitum were obtained, and the main phases were plagioclase, potassium feldspar and quartz, and a few samples also contained illite, pyrite, iron dolomite, calcite, iron amphibole and chlorite, etc. The relative total content of feldspar phases was 61.9%-82.4%, and the relative content of quartz was 12.6%-33.6%. The XRD Fourier fingerprint analysis method of Maifanitum with 13 common peaks as the characteristic fingerprint information was established, and the similarity calculated by the mean correlation coefficient method was 0.920 9-0.997 7, the similarity calculated by the mean angle cosine method was 0.940 5-0.998 4, the similarity calculated by the median correlation coefficient method was 0.921 1-0.997 5, and the similarity calculated by the median angle cosine method was 0.947 5-0.998 2. ConclusionThe polarized light microscopic identification characteristics of Maifanitum are mainly plagioclase, quartz and potassium feldspar, and the technique of powder crystal XRD Fourier fingerprint analysis can be used for the identification of Maifanitum.

18.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 122-129, 2023.
Article in Chinese | WPRIM | ID: wpr-973753

ABSTRACT

ObjectiveTo establish the quality standard for Fraxini Cortex(Fraxinus chinensis) dispensing granules based on standard decoction, and to provide a basis for the quality control of this dispensing granules. MethodHigh performance liquid chromatography(HPLC) specific chromatograms of 15 batches of Fraxini Cortex(F. chinensis) standard decoctions and 3 batches of Fraxini Cortex(F. chinensis) dispensing granules were established with the mobile phase of 0.1% phosphoric acid aqueous solution(A)-acetonitrile(B) for gradient elution(0-10 min, 12%-15%B; 10-30 min, 15%-32%B) and the detection wavelength of 220 nm. And similarity evaluation, cluster analysis and principal component analysis(PCA) were also carried out. HPLC quantitative analysis of multi-components by single marker(QAMS) was established to determine the contents of the main components in the standard decoctions and dispensing granules. The contents of the corresponding components in Fraxini Cortex(F. chinensis) decoction pieces were also detected, and the transfer rates from decoction pieces to standard decoctions and dispensing granules were calculated. ResultThe similarities between specific chromatograms of 15 batches of Fraxini Cortex(F. chinensis) standard decoctions and 3 batches of Fraxini Cortex(F. chinensis) dispensing granules were all>0.9, and 7 common peaks were identified. The results of cluster analysis and PCA showed that there was some differences in the composition of different batches of standard decoctions, but did not show aggregation of origin. As the standard decoctions, the extract rate was 6.18%-11.62%, the contents of esculin, syringin, fraxin, esculetin, fraxetin, calceolarioside B were 44.92-103.51, 1.36-11.87, 33.26-90.73, 4.63-29.75, 2.40-16.86, 2.49-17.35 mg·g-1, and the transfer rates from decoction pieces to standard decoction were 25.21%-42.54%, 52.57%-88.84%, 43.43%-79.45%, 49.15%-88.27%, 49.22%-72.69%, 27.66%-47.67%, respectively. The extract rates of Fraxini Cortex(F. chinensis) dispensing granules were 10.4%-10.7%, the transfer rates of the above six components from decoction pieces to dispensing granules were 42.76%-43.17%, 80.01%-80.90%, 59.59%-59.88%, 51.35%-52.67%, 60.50%-60.93%, 37.98%-38.37%, respectively, which were generally consistent with the transfer rates from decoction pieces to standard decoctions. ConclusionThe established quality control standard of Fraxini Cortex(F. chinensis) dispensing granules based on standard decoctions is reasonable and reliable, which can provide reference for the quality control and process research of this dispensing granules.

19.
Chinese Journal of Experimental Traditional Medical Formulae ; (24): 37-44, 2023.
Article in Chinese | WPRIM | ID: wpr-973743

ABSTRACT

ObjectiveTo establish the specific chromatogram and thin layer chromatography(TLC) identification method of Kaixinsan(KXS) samples, in order to clarify the key quality attributes and provide reference for the quality evaluation of KXS. MethodHigh performance liquid chromatography(HPLC) specific chromatogram of KXS was developed with YMC Hydrosphere C18 column(4.6 mm×250 mm, 5 μm), the mobile phase was acetonitrile(A)-0.2% formic acid aqueous solution(B) for gradient elution(0-15 min, 2%-20%A; 15-25 min, 20%-25%A; 25-30 min, 25%-30%A; 30-45 min, 30%-31%A; 45-50 min, 31%-44%A; 50-65 min, 44%-45%A; 65-73 min, 45%-75%A; 73-95 min, 75%-100%A; 95-105 min, 100%A; 105-105.1 min, 100%-2%A; 105.1-120 min, 2%A), the detection wavelength was 320 nm. Ultra high performance liquid chromatography-linear ion trap-electrostatic field orbitrap mass spectrometry(UHPLC-LTQ-Orbitrap MS) was used to identify the chemical components of KXS with electrospray ionization(ESI), negative ion mode and scanning range of m/z 50-2 000. TLC identification methods for Poria and Ginseng Radix et Rhizoma in KXS were established. ResultThere were 11 common peaks in the specific chromatogram of KXS, attributed to Polygalae Radix, Poria and Acori Tatarinowii Rhizoma. Taking peak 9(α-asarone) as the reference peak, the relative standard deviations of the retention times of 15 batches of KXS samples were<0.2%. A total of 34 compounds were identified by UHPLC-LTQ-Orbitrap MS, including terpenoids, phenylpropanoids, oligosaccharides and ketones. The established TLC had good separation and was rapid, reliable, simple, feasible, suitable for the identification of Poria and Ginseng Radix et Rhizoma in KXS. ConclusionThe specific chromatogram and TLC of KXS are stable and reproducible. The material basis of KXS is basically clarified by MS, which can provide a reference for the development and quality control of KXS.

20.
Journal of Environmental and Occupational Medicine ; (12): 571-576, 2023.
Article in Chinese | WPRIM | ID: wpr-973649

ABSTRACT

Background Individual monitoring of occupational external exposure is an essential part of the occupational health management of radiation workers, and is an important basis for the evaluation of individual absorbed dose and the diagnosis of occupational radiation diseases. Continuous participation of monitoring service providers in intercomparison is a fundamental quality assurance for routine monitoring, which can identify problems and improve them in time. Objective Taking the Laboratory of Radiation Protection in Shanghai Institute of Preventive Medicine as an example, to evaluate the performance of an individual occupational external dose monitoring system in the laboratory, identify influencing factors of the monitoring results, and provide a basis for improving the quality of daily monitoring by analyzing the process and results of a national intercomparison of individual dose monitoring. Methods According to the Testing criteria of personnel dosimetry performance for external exposure (GBZ 207-2016), and the relevant requirements of Class II (photon) inspection, a total of 20 groups of blind sample dosimeters were measured for four consecutive years from 2018 to 2021. The radiation energy source of each group was identified, and related personal dose equivalent Hp(10), the uncertainty of measurement results, and the deviation between the reported value and the reference value were calculated. The national intercomparison process and results of individual dose monitoring were also analyzed. Results The energy sources of the blind samples in the tested laboratory for four years were N100 or Cs-137. The reported dose values of the blind samples were 0.57-4.61 mSv, the combined uncertainties were 0.043-0.365 mSv, the expanded uncertainties (k=2) were 0.09-0.73 mSv, and the relative expanded uncertainties (k=2) were 13.8%-16.4%. The single-group performance ∣Pi∣ of 20 sets of blind samples in the four years was ≤0.10, the yearly comprehensive performance of 5 sets of blind samples was ≤0.10, and the yearly Q score of the test report was >15 points. The laboratory achieved excellent results in the national intercomparison of individual dose monitoring in four consecutive years, except the Q value not reaching full score. Conclusion The laboratory exhibits standardized data processing of individual dose monitoring, generates accurate and reliable results, and meets the requirements of relevant national standards; but it should continue to participate in the national intercomparison of individual dose monitoring, strengthen the angular response research of energy identified dosimeter, improve the monitoring ability of low-dose X-rays, analyze the key points of reducing the uncertainty of measurement results, and continuously improve the monitoring ability.